Measurement Specifications |
|
Norminal Output Power |
3kVA |
Output Voltage (AC) |
High Range – 0-270Vrms / Low Range – 0-135Vrms |
Output Voltage (DC) |
0-380V DC |
Maximum Continuous Output Power |
3kVA |
Maximum Inrush Output power |
2x IN for 3 sec / 1.5x IN for 6 sec |
Maximum Output current (continuous) |
High Range – 11.1A, Low Range – 22.2A |
Maximum Output current (Inrush) |
High Range – 22.2A (3 sec), 16.65A (6 sec) |
|
Low Range 44.4A (3 sec), 33.3A (6 sec) |
Output Frequency (Full Signal) |
DC~3kHz |
Output Frequency (Small Signal) |
DC~10kHz |
Slew rate |
6V/µs |
Output Voltage Stability/Regulation |
Better than 0.1% |
Output Voltage line regulation |
Better than 0.1% |
Output Voltage Accuracy |
Better than 0.5% |
THD |
Better than 0.3% (at nominal output voltage with linear load) |
Output Noise |
<500mVrms |
Recovery time of Output Waveform |
Better than 50µs |
Max Compensated Drop on Wires (w.r.t voltage setting) |
5% |
Recorvery time of drop on wires |
Less than 200ms |
Maximum Crest Factor Output (Current) |
4:1 |
Maximum number of parallel units stackable |
9x3kVA (27kVA max) |
|
|
Mechanical/Environmental |
|
Display |
972×272 dot full colour super wide screen TFT, white LED backlit |
Dimensions |
2U High – 88H×433W×679D mm excluding feet |
Weight |
21.5kg |
Input Power supply |
1 Phase 90 〜270Vrms, 40 〜 440Hz, 3.5kVAmax (7kVA inrush) |
Operating Temperature |
-5 to +40°C |
Storage Temperature |
-10 °C to +70°C |
Input Topology |
1 Phase, Isolated, Power Factor corrected, Auto-ranging |
|
|